AnalytikJena CL-1000 UV Crosslinker

  • AnalytikJena  CL-1000 UV Crosslinker
Price:
Discontinued
Weight:
19.00 LBS
Availability:
Discontinued


Product Description

The AnalytikJena CL-1000 has been discontinued and replacement by CL-3000 UV Crosslinker.

 

AnalytikJena's Model CL-1000 UV Cross-linker supplies uniform intensity overhead UV exposure of materials. It utilizes shortwave ultraviolet energy to bond DNA to a medium. Ultraviolet Crosslinking for attaching nucleic acids to a membrane takes seconds as compared to oven baking.  AnalytikJena Crosslinkers offer researchers an instrument to quickly, safely and efficiently expose samples to a controlled amount of ultraviolet radiation. A unique UV sensor continually measures the UV energy and automatically adjusts to variations in UV intensity that occurs as the UV tubes age. This same UV sensor feedback measurement system allows you to set UV sample exposure, which automatically deactivates the UV sources when the set UV energy dose has been achieved.

Applications

  • Crosslinking of DNA or RNA to nitrocellulose, nylon or reinforced nitrocellulose,
  • PCR sample contamination control,
  • Photonicking of DNA,
  • Testing RNA function,
  • Rapid site mapping,
  • UV sterilization and sanitization,
  • UV curing.

Features

  • Preset and manual controls for ultraviolet or time exposures:
    • Factory presetting's deliver 120,000 microjoules or 5 minutes of exposure,
    • Maximum UV energy setting of 999,900 microjoules per cm2.
  • Integrated UV sensor for measurement and exposure control is calibrated at the factory to ensure accuracy and reliability,
  • If user requirements and applications change, the CL-1000 provides the unique ability to change the ultraviolet wavelength and recalibrate the UV sensor and microprocessor to the new UV wavelength with new UV tubes and re-calibration,
  • Microprocessor output control optimizes the use of energy while ensuring consistent, maximum energy efficiency and output,
  • Large LED display with touch panel displays time or energy settings,
  • Window on the door allows viewing of the process yet blocks the UV radiation,
  • Small footprint for benchtop use,
  • Five 8-watt ultraviolet tubes provide uniform overhead ultraviolet illumination.

Model

Part Numbers

Wavelength

115V

230V

100V

CL-1000 95-0174-01 95-0174-02 95-0174-03 254nm
CL-1000L 95-0228-01 95-0228-02 95-0228-03 365nm
CL-1000M 95-0230-01 95-0230-02 95-0230-03 302nm

Specifications

  • Display: LED
  • Controls: Touch pad
  • UV exposure output: 120,000 microjoules or 5 minutes (adjustable); maximum UV energy setting of 999,900 microjoules per cm2
  • Watts: 8 watt
  • UV Source:
    • Model CL-1000: Shortwave 254nm UV for UV crosslinking membranes, UV Curing, sterilization
    • Model CL-1000L: Longwave 365nm UV for UV curing, non-destructive testing
    • Model CL-1000M: Midrange 302nm UV for photochemical reactions, UV crosslinking
  • Dimensions:
    • Exterior: 13.7D x 15.6W x 8.75H in. (248 x 396 x 222mm)
    • Interior:12D x 10W x 5H in. (305 x 254 x 127mm)
  • Weight: 15.5 lbs. (7.5 kg)

Optional Accessories

Literature

adobe-pdf-icon-transparent-halfinch.pngSee Operating Manual

---

Warranty Information

AnalytikJena's products are guaranteed to be free of defects in materials, workmanship and manufacture for one (1) year from date of purchase, except as follows:
- Consumable and disposable parts are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
- UV tubes and filters are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
- AnalytikJena Transilluminators are guaranteed to be free from defects in manufacture and materials for two (2) years from date of purchase.

If equipment failure or malfunction occurs during the warranty period, AnalytikJena shall examine the inoperative equipment and have the option of repairing or replacing any part(s) which, in the judgment of AnalytikJena , were originally defective or became so under conditions of normal usage and service.

No warranty shall apply to this instrument, or part thereof, that has been subject to accident, negligence, alteration, abuse or misuse by the end-user. Moreover, AnalytikJena makes no warranties whatsoever with respect to parts not supplied by AnalytikJena or that have been installed, used and/or serviced other than in strict compliance with instructions appearing in this manual.

In no event shall AnalytikJena be responsible to the end-user for any incidental or consequential damages, whether foreseeable or not, including but not limited to property damage, inability to use equipment, lost business, lost profits, or inconvenience arising out of or connected with the use of instruments produced by AnalytikJena . Nor is AnalytikJena liable or responsible for any personal injuries occurring as a result of the use, installation and/or servicing of equipment.

This warranty does not supersede any statutory rights that may be available in certain countries.

Find Similar Products by Category

Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!