Loading... Please wait...

Categories

Our Newsletter


AnalytikJena UVP Solo Elite

  • UVP Solo Elite
  • UVP Solo Elite Countertop Size
  • UVP Solo Elite -Large, integrated touch screen
Price:
$12,539.97
SKU:
AJ 849-97-0944-01
Weight:
49.00 LBS
Shipping:
Calculated at checkout


Product Description

The Analytik Jena UVP Solo Elite is a compact system for the rapid processing of gel analysis and documentation in labs.

Applications

  • Gel analysis,

analytikjena-uvp-solo-elite-gel-analysis.jpg

  • DNA Applications - Most commonly used DNA Dyes such as EtBr, GelRed, GelGreen, SYBR Safe, SYBR Green.

  • Protein Applications – Coomassie Blue and Silver stain(with UV to white converter plate), Satin free Gel, SYPRO Ruby(and other dyes with similar excitation and emission range),

  • Western blotting – Colorimetric blot, CF488, Cy2, Cy3 (or other dyes with similar excitation and emission range),

  • Colony Applications – Bacterial colony plate, Clonogenic assay(with UV to white converter plate)

  • Imaging,

  • Documentation.

Features

  • All in one automated, benchtop, easy to use and compact system for gel documentation,

  • User friendly VisionWorks acquisition and analysis software to acquire gel images instantly in one-click,

  • Budget friendly price with most competitive market specifications,

  • Image capture and analysis optimized by large 11.6” integrated touch screen with user friendly software,

TOUCHSREEN

  • High resolution 6.3MP Color or monochrome camera with automated lens for reducing post image processing for high quality images and eliminating the need for multiplexing,

  • UVP Transilluminator with 16.8x21 cm illumination for different gel sizes and images saved on USB Drive, system or network computer by easy access data storage (7 USB Ports),

  • Three-position automated filter tray with pre-installed filters of our choice, which can be replaced according to the application need. An Ethidium Bromide Filter is fixed as default in system,

  • Gel Imaging applications enabled by epi-white and epi-blue LED lights,

  • Wide front door with UV light for safe operation of users, with automatic turn off safety switch when door opens,

  • UV light turned into visible light by two converter plates –Visi Blue & Visi White for placing on top of the UV Transilluminator,

  • Auto focus and auto exposure actions done in one-touch with streamlined 1D analysis for band fine editing,

  • Advanced calibration supported for flat fielding, dark frame and photon flux and auto classification for colony sample,

  • All activities recorded within Visionworks during a session using master audit trail.

Specifications

Models
Camera 115V 230V
Monochrome AJ 849-97-0944-01 AJ 849-97-0944-02
Color AJ 849-97-0944-03 AJ 849-97-0944-04

 

  • Broad band filter (535nm – 660nm) pre-mounted on the Elite Mount

  • Camera Specifications:  

    • 6.3 MP (available in monochrome or color)
    • Automated lens,
    • 3072 x 2048 pixel resolution,
    • 65536 Grey Scales(16-bit),
    • Max. Sample area – 16.8x21 cm
    • CMOS sensor
  • 11.6” large integrated touch screen computer with 128GB of storage on a Solid-State Drive (SSD)

  • Integrated shutoff UV door safety switch

  • 3-position automated emission filter tray with pre-installed filters

  • Overhead white and epi blue LEDs

  • 7 rear, one side USB ports for flash drive data export, USB-to-Ethernet connection or use with mouse of keyboard

  • Dimensions (H x W x D):  61 x 46 x 38 cm (24 x 18 x 15 in)

  • Includes UVP Elite UV Transilluminator (302 nm). 

Optional Accessories

 

Warranty Information

AnalytikJena's products are guaranteed to be free of defects in materials, workmanship and manufacture for one (1) year from date of purchase, except as follows:
- Consumable and disposable parts are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
- UV tubes and filters are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
- AnalytikJena Transilluminators are guaranteed to be free from defects in manufacture and materials for two (2) years from date of purchase.

If equipment failure or malfunction occurs during the warranty period, AnalytikJena shall examine the inoperative equipment and have the option of repairing or replacing any part(s) which, in the judgment of AnalytikJena , were originally defective or became so under conditions of normal usage and service.

No warranty shall apply to this instrument, or part thereof, that has been subject to accident, negligence, alteration, abuse or misuse by the end-user. Moreover, AnalytikJena makes no warranties whatsoever with respect to parts not supplied by AnalytikJena or that have been installed, used and/or serviced other than in strict compliance with instructions appearing in this manual.

In no event shall AnalytikJena be responsible to the end-user for any incidental or consequential damages, whether foreseeable or not, including but not limited to property damage, inability to use equipment, lost business, lost profits, or inconvenience arising out of or connected with the use of instruments produced by AnalytikJena . Nor is AnalytikJena liable or responsible for any personal injuries occurring as a result of the use, installation and/or servicing of equipment.

This warranty does not supersede any statutory rights that may be available in certain countries.

Find Similar Products by Category

Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!