Product Description
The MRC Labs series syringe pumps for control of single syringes are TJ-1A, TJ-2A and TJ-3A. The TJ-1A pump is a single-channel micro syringe pump which only has infusion mode, and the TJ-2A and -3A pumps are single-channel micro syringe pumps which have infusion/withdrawal mode. They each combine precision, compact size with ease of installation and operation.
Features
-
Precision control by syringe selection either from the table of manufacturers (showing manufacturer, material and size) or by specification of syringe size, with input the inner diameter of the syringe barrel.
-
Memory function: Select resume operation or remain stopped when power returns after an interruption
-
Signal output: Start/Stop output, cw/ccw output (open collector)
-
Calibration: Acquire accurate volume through calibration
-
Fast forward & fast reverse: Infusion or withdrawal at the max. speed.
-
Easy to operate: Combining big screen LCD display with rotary coded switch and membrane keypad makes the operation simple and prompt.
-
The TJ-1A and -2A pumps hold standard size glass syringes from 5µl to 1ml, while the TJ-3A system is compatible with syringe s capacities from 10 µL to 10 mL, operating all with high accuracy & small flow rate liquid transfers.
-
Accurate distance control and broad linear speed range (7.9 µm/min - 79.4 mm/min) can meet versatile requirements.
-
Fast forward & fast reverse for infusion or filling at the max. speed,
-
The vertical and horizontal installation structure allows the pump driver to be easily mounted on micro-positioning, micromanipulator, and stereotaxic tools.
-
Multiple Working Modes: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous.
-
Memory retains parameters; no need to be reset when power returns after an interruption.
Specifications
-
Working modes:
-
TJ-1A: Infusion only
-
TJ-2A, TJ-3A: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous
-
Linear speed: 7.94 µm/min - 79.4 mm/min,
-
Adjusting resolution: 7.9 µm/min,
-
Accuracy: < +/- 0.5% error in the condition of > 30% of max. infusion distance,
-
Calibration: Acquire accurate volume through calibration,
-
Distance resolution: 0.165 µm,
-
Full stroke linear force: >20 N,
-
Max. infusion distance: 70 mm
- Controls
- Interface: Membrane keypad and rotary encoded switch,
- Display: 128 x 64 pixel graphical LCD
- External control: Start/Stop control, fast forward control, fast reverse control
- Communication interface: RS 485,
- Signal output: Start/Stop output, cw/ccw output (Open Collector),
- Memory function: Select "resume operation" or "remain stopped" on interrupted power return,
- User-defined glass Syringe: Save 4 inner diameters of user-defined glass syringe barrel,
-
Operation Temperature: 0°C - 40°C,
-
Operation relative humidity: <80%, non-condensing,
-
TJ-3A Programmability:

-
Ingress Protection Rating: IP21
-
Input Power supply: 90 - 230VAC 50/60Hz for 12 VDC
-
Max Power consumption: 10 W
Acceptable glass syringes: 5 µL - 1000 µL:
|
Syringe (μl) |
Syringe ID (mm) |
Flow Rate (nl/min-μl/min) |
|
5 |
0.35 |
0.764 - 7.64 |
|
10 |
0.5 |
1.559 - 15.59 |
|
25 |
0.8 |
3.991 - 39.91 |
|
50 |
1.1 |
7.546 - 75.46 |
|
100 |
1.6 |
15.96 - 159.6 |
|
250 |
2.3 |
32.99 - 329.9 |
|
500 |
3.25 |
65.87 - 658.7 |
|
1000 |
4.61 |
132.5 - 1325 |
Reference TJ-1A, -2A Compatible Syringes
| Unimetrics | Spec(μL) | 10 | 25 | 50 | 100 | 250 | 500 | 1000 |
| Unimetrics | ID(mm) | 0.46 | 0.73 | 1.03 | 1.46 | 2.3 | 3.26 | 4.61 |
| Hamilton | Spec(μL) | 10 | 25 | 50 | 100 | 250 | 5000 | -- |
| Hamilton | ID(mm) | 0.46 | 0.73 | 1.03 | 1.46 | 2.3 | 3.26 | -- |
| SGE | Spec(μL) | -- | 25 | 50 | 100 | 250 | 500 | -- |
| SGE | ID(mm) | -- | 0.73 | 1.03 | 1.46 | 2.3 | 3.26 | -- |
Acceptable TJ-3A Syringes (1mL - 60 mL)
|
Syringe (mL) |
ID |
Flow Rate {µL/min-ml/min) |
|
1 |
4.72 |
0.139-1.39 |
|
2 |
9 |
0.505-5.05 |
|
5 |
13.1 |
1.07-10.7 |
|
10 |
16.6 |
1.718-17.18 |
|
20 |
19 |
2.251-22.51 |
|
30 |
23 |
3.298-32.98 |
|
60 |
29.14 |
5.295-52.95 |
Reference TJ-3A Compatible Syringes
| Unimetrics | Spec(μL) | 10 | 25 | 50 | 100 | 250 | 500 | 1000 |
| Unimetrics | ID(mm) | 0.46 | 0.73 | 1.03 | 1.46 | 2.3 | 3.26 | 4.61 |
| Beckton-Dickinson | Spec(mL) | 1 | 3 | 5 | 10 | 20 | 30 | 60 |
| Beckton-Dickinson | ID(mm) | 4.7 | 8.59 | 11.99 | 14.48 | 19.05 | 21.59 | 26.6 |
| Hamilton | Spec(mL) | 1 | 2.5 | 5 | 10 | 25 | 50 | -- |
| Hamilton | ID(mm) | 4.61 | 7.28 | 10.3 | 14.57 | 23.03 | 32.57 | -- |
Dimensions and Weight
| TJ-1A | TJ-2A | TJ-3A | ||
| Dimensions (LxWxH)(mm) | Drive | 180 x 46 x 78 | 180 x 46 x 78 | 245 x 100 x 95 |
| Dimensions (LxWxH)(mm) | Controller | 170 x 108 x 65 | 170 x 108 x 65 | 170 x 108 x 70 |
| Weight (Kg) | Drive | 0.5 | 0.6 | 1.3 |
| Weight (Kg) | Controller | 0.5 | 0.8 | 0.8 |
Default Currency
EURO
ARA - ARGENTINA
AUD - AUSTRALIA
BRL - BRAZIL
CAD - CANADA
CHF - SWITZERLAND
CLP - CHILE
CNY - CHINA
CZK - CZECH REPUBLIC
DKK - DENMARK
GBP - GREAT BRITAIN
IDR - INDONESIA
ILS - ISRAEL
INR - INDIA
JPY -JAPAN
KRW - SOUTH KOREAN REPUBLIC
MXN - MEXICO
MYR - MALAYSIA
NOK - NORWAY
NZD - NEW ZEALAND
PAB - PANAMA
PHP - PHILIPPINES
PKR - Pakistan
PLN - POLAND
RUB - RUSSIA
SAR - SAUDI ARABIA
SEK - SWEDEN
SGD - SINGAPORE
THB - THAILAND
TRY - TURKEY
TWD - TAIWAN
UAH - UKRAINE
ZAR - SOUTH AFRICA